What was found
INSPECTION TYPE:C FWD CARGO COMPT TORQUE BOX UPPER ACCESS PANEL UPPER SURFACE FOUND SURFACE CORROSION AT STA 660-680 RBL 50 TO RBL 57. CORROSION BLEND OUT 0.055" X 1" X 4" EXCEED SRM 53-10-01 FIG 1 LIMITS, WEB REPLACED & INSTALLED AS PER SRM 51-10-01 PG 9 & 51-30-02.