What was found
INSPECTION TYPE:C RT BLG W/W STA 1438 FRAME ATT HOLE FOUND CRACKED RBL 116 WL 156, CRACK LENGTH 3/8". RT BLG W/W BS 1438 RBL 116 WL 152 TO WL 165 FRAME REPAIRED AS PER SRM 51-40-03 FIG 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C RT BLG W/W STA 1438 FRAME ATT HOLE FOUND CRACKED RBL 116 WL 156, CRACK LENGTH 3/8". RT BLG W/W BS 1438 RBL 116 WL 152 TO WL 165 FRAME REPAIRED AS PER SRM 51-40-03 FIG 2.