As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C FWD CARGO COMPT LT STA 860 IN BETWEEN LBL32-45 FLOORBEAM UPPER CHORD FOUND CORROSION. CORROSION BLEND OUT 0.030" BY 3/4" BY 2" EXCEED SRM LIMIT. FWD CARGO COMPT BS 860 LBL 32 TO LT O/B FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 51-40-04 FIG2.