As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C FWD CARGO COMPT STA 660 IN BETWEEN LBL 7 AND RBL 7 FLOORBEAM UPPER CHORD ATT PLATE FOUND CORROSION. CORROSION BLEND OUT 0.060" BY 1/2" BY 1.5" EXCEED SRM LIMIT. FWD CARGO COMPT BS 600 LBL 7 TO RBL 7 FLOORBEAM UPPER CHORD ATTACH PLATE REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.