As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C FWD CARGO COMPT STA 640-650 BL 0 FLOORBEAM UPPER CHORD ATT PLATE FOUND CORROSION. CORROSION BLEND OUT 0.063" BY 1/2" BY 3/4" EXCEED SRM LIMIT. FWD CARGO COMPT BS 640-650 LBL5-RBL5 FLOORBEAM UPPER CHORD ATTACH PLATE REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.