As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C FWD CARGO COMPT RT MAIN DECK FLOORBEAM LOWER CHORD SPLICE PLATE LOWER SURFACE FOUND SURFACE CORROSION AT STA 680 TO STA 700 RBL12. CORROSION BLEND OUT 0.019" BY 1/2" BY 1" EXCEED SRM LIMIT. FWD CARGO COMPT RT MAIN DECK FLOORBEAM LOWER CHORD SPLICE PLATE REPLACED AS PER SRM 51-10-01 PG 9 JUST AT STA 680-700 RBL 12 AREA.