What was found
INSPECTION TYPE:C AFT CARGO COMPT RT STA 1620 IN BETWEEN RBL32 AND RBL45 FLOORBEAM CHORD FOUND CORROSION. CORROSION BLEND OUT 0.024" BY 1.5" BY 1.5". AFT CARGO COMPT RT STA 1620 IN BETWEEN RBL 32 AND RBL 45 FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 51-40-04 FIG 2.