As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C U/D BS440 MOST OF FLOORBEAM FASTENER HOLE FOUND SHORT EDGE BELOW 0.44" AS MARKED AT BETWEEN LBL 44 TO LBL 53 AND RBL 44 TO RBL 53 AREA. U/D BS 440 BETWEEN LBL68 TO RBL68 FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 53-10-07 FIG 14 REFER NRC7031 FOR WORKING DETAIL L/R BL44 TO L/R BL53 FLOORBEAM ATTACH GUSSETS REPLACED AS PER SRM 51-10-01 PG 9.