As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C EMP - BS 2598 BULKHEAD UPPER CENTER SECTION RT LOWER SUSPECT CRACK AT RBL 36. CRACK LENGTH 1.25 INCH. EMP - BS 2598 BULKHEAD UPPER CENTER SECTION RT LWR FLOOR SUPPORT REPAIRED AS PER RS R53-83-25547 JUST BETWEEN RBL 26 AND RBL 37 AND UPS ENGINEERING FILE 747-53-20310.