As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C RT BS 340 UPPER DECK FLOORBEAM UPPER CHORD AREA 1 FASTENER HOLE FOUND CRACKED AT FRAME WEB LAYER THROUGH THICKNESS, CRACK LENGTH 3/32". CABIN U/D BS340 RT FRAME WEB AT WL310 AREA REPAIRED AS PER SRM 53-10-04 FIG 102 AND RS R53-10-35527 REPEAT INSPECTION IS REQUIRED AS PER RS R53-10-35527 ITEM 3 AND UPS EO B747-5310-24841-A.