BS 680 LBL4 FLOORBEAM UPPER SURFACE CORROSION. CORROSON BLEND OUT 0.055" BY 2" BY 4" EXCEED SRM LIMIT. M/D BS680 LBL4 FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 51-40-04 FIG 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 680 LBL4 FLOORBEAM UPPER SURFACE CORROSION. CORROSON BLEND OUT 0.055" BY 2" BY 4" EXCEED SRM LIMIT. M/D BS680 LBL4 FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 51-40-04 FIG 3.