What was found
INSPECTION TYPE-C M/D BS 820 LT SIDE TENSION TIE TO FRAME CONNECTION FASTENER HOLE FOUND CRACK AT WEB DOUBLER. CRACK LENGTH 0.040 INCH. M/D BS820 LHS FRAME ATTACHED DOUBLER BETWEEN STR9L TO STR12L AREA REPLACED AND INSTALLED IAW SRM 51-10-01 PG9 AND 51-30-02.