What was found
RT NWW VERTICAL BEAM WEB AT BS 300 FOUND CRACK AT WL 171 INSULATION BLANKET STAND OFF, CRACK LENGTH 1/8". WEB REPLACED AS PER SRM 51-10-01 PG 9 AND INSTALLED PER SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT NWW VERTICAL BEAM WEB AT BS 300 FOUND CRACK AT WL 171 INSULATION BLANKET STAND OFF, CRACK LENGTH 1/8". WEB REPLACED AS PER SRM 51-10-01 PG 9 AND INSTALLED PER SRM 51-30-02.