What was found
BS 980 LBL 60 FLOORBEAM UPPER SURFACE CORROSION. CORROSION BLEND OUT 0.068" BY 2" BY 2" EXCEED SRM 53-10-01 FIG 1 LIMITS. BS 980 LBL 20" TO LBL 70" FLOORBEAM UPPER CHORD REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.