What was found
BS 1020 LBL 25 FLOORBEAM UPPER SURFACE FOUND CORROSION. CORROSION BLEND OUT 0.041" BY 2" BY 2". FLOORBEAM REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02 REFER NRC 6539 FOR WORKING DETAIL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1020 LBL 25 FLOORBEAM UPPER SURFACE FOUND CORROSION. CORROSION BLEND OUT 0.041" BY 2" BY 2". FLOORBEAM REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02 REFER NRC 6539 FOR WORKING DETAIL.