What was found
INSPECTION TYPE:C M/D CENTER SECTION UPPER SURFACE FOUND CORROSION AT BS 1180 RBL 98. CORROSION BLEND OUT 0.050" BY 2" BY 4" EXCEED SRM LIMIT. REPAIRED AS PER RS R57-14-35603 AND UPS ENGINEERING FILE NUMBER 747-57-20115.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D CENTER SECTION UPPER SURFACE FOUND CORROSION AT BS 1180 RBL 98. CORROSION BLEND OUT 0.050" BY 2" BY 4" EXCEED SRM LIMIT. REPAIRED AS PER RS R57-14-35603 AND UPS ENGINEERING FILE NUMBER 747-57-20115.