What was found
BS 230 TO 240 RBL74 TO 76 TIE DOWN TRACK O/B FLANGE FOUND CORROSION. CORROSION BLEND OUT 0.032" BY 1/2" BY 10" EXCEED SRM LIMIT. TIE DOWN TRACK REPAIRED AS PER SRM 53-10-05 FIG 1A JUST AT RBL75 BETWEEN BS 230 AND 330.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 230 TO 240 RBL74 TO 76 TIE DOWN TRACK O/B FLANGE FOUND CORROSION. CORROSION BLEND OUT 0.032" BY 1/2" BY 10" EXCEED SRM LIMIT. TIE DOWN TRACK REPAIRED AS PER SRM 53-10-05 FIG 1A JUST AT RBL75 BETWEEN BS 230 AND 330.