What was found
BS 400-405 RBL11 TIE DOWN TRACK O/B A/NUT AREA LOWER FACE FOUND CORROSION. CORROSION BLEND OUT 0.030" BY 7/8" BY 5" EXCEED SRM LIMIT. TIE DOWN TRACK AT RBL 11 BS 320-410. REPLACED AS PER SRM 51-10-01 PG9 WORKS DETAIL REF NRC 50350.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 400-405 RBL11 TIE DOWN TRACK O/B A/NUT AREA LOWER FACE FOUND CORROSION. CORROSION BLEND OUT 0.030" BY 7/8" BY 5" EXCEED SRM LIMIT. TIE DOWN TRACK AT RBL 11 BS 320-410. REPLACED AS PER SRM 51-10-01 PG9 WORKS DETAIL REF NRC 50350.