What was found
BS 470-480 RBL 33 TIE DOWN TRACK I/B FLANGE FOUND CORROSION. CORROSION BLEND OUT 0.021" BY 1" BY 6" EXCEED SRM LIMIT. BS 460-510 RBL33 TIE DOWN TRACK REPLACED AS PER SRM 51-10-01 PG 9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 470-480 RBL 33 TIE DOWN TRACK I/B FLANGE FOUND CORROSION. CORROSION BLEND OUT 0.021" BY 1" BY 6" EXCEED SRM LIMIT. BS 460-510 RBL33 TIE DOWN TRACK REPLACED AS PER SRM 51-10-01 PG 9.