What was found
BS 460-480 RBL 11 TIE DOWN TRACK O/B FLANGE FOUND CORROSION. CORROSION BLEND OUT 0.025" BY 1/2" BY 10" EXCEED SRM LIMIT. TIE DOWN TRACK REPLACED AS PER SRM 51-10-01 PG 9 JUST AT RBL 11 BETWEEN STA 410 AND 510 (REFER NRC 50679).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 460-480 RBL 11 TIE DOWN TRACK O/B FLANGE FOUND CORROSION. CORROSION BLEND OUT 0.025" BY 1/2" BY 10" EXCEED SRM LIMIT. TIE DOWN TRACK REPLACED AS PER SRM 51-10-01 PG 9 JUST AT RBL 11 BETWEEN STA 410 AND 510 (REFER NRC 50679).