What was found
BS 410-460 RBL 11 TIE DOWN TRACK I/B FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.029" BY 1" BY 9" EXCEED SRM LIMIT. TIE DOWN TRACK REPLACED AS PER SRM 51-10-01 PG 9 JUST AT RBL 11 BETWEEN STA 410 AND 510.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 410-460 RBL 11 TIE DOWN TRACK I/B FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.029" BY 1" BY 9" EXCEED SRM LIMIT. TIE DOWN TRACK REPLACED AS PER SRM 51-10-01 PG 9 JUST AT RBL 11 BETWEEN STA 410 AND 510.