What was found
TIE DOWN FLANGE PLATE FOUND CORROSION JUST AT BS 1880 LBL30. CORROSION BLEND OUT 0.016" BY 1/2" BY 1" EXCEED SRM LIMIT. TIE DOWN FTG REPLACED AS PER MM 20-51-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TIE DOWN FLANGE PLATE FOUND CORROSION JUST AT BS 1880 LBL30. CORROSION BLEND OUT 0.016" BY 1/2" BY 1" EXCEED SRM LIMIT. TIE DOWN FTG REPLACED AS PER MM 20-51-01.