What was found
TIE DOWN FTG FLANGE FOUND CORROSION JUST AT BS 1680 LBL40. CORROSION BLEND OUT 0.049" BY 3/4" BY 3/4" EXCEED SRM LIMIT. PLATE REPLACED AS PER MM 20-51-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TIE DOWN FTG FLANGE FOUND CORROSION JUST AT BS 1680 LBL40. CORROSION BLEND OUT 0.049" BY 3/4" BY 3/4" EXCEED SRM LIMIT. PLATE REPLACED AS PER MM 20-51-01.