What was found
BS 2160-2180 LBL 97-100 FLOOR WEB FOUND CORROSION. CORROSION BLEND OUT 0.050" BY 5/8" BY 1" EXCEED SRM LIMIT. BS 2160-2180 LBL97-100 FLOOR WEB REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 2160-2180 LBL 97-100 FLOOR WEB FOUND CORROSION. CORROSION BLEND OUT 0.050" BY 5/8" BY 1" EXCEED SRM LIMIT. BS 2160-2180 LBL97-100 FLOOR WEB REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.