What was found
BS 1960 RBL60 I/B FLOOR FTG FOUND CRACKED, CRACK LENGTH 1.5". FLOOR SUPPORT FITTING REPLACED AS PER SRM 51-10-01 P.9 AND INSTALLED AS PER SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1960 RBL60 I/B FLOOR FTG FOUND CRACKED, CRACK LENGTH 1.5". FLOOR SUPPORT FITTING REPLACED AS PER SRM 51-10-01 P.9 AND INSTALLED AS PER SRM 51-30-02.