What was found
INSPECTION TYPE:C M/D BS 2208 RBL 93 FLOOR SUPPORT FOUND CORROSION. CORROSION BLEND OUT 0.020" BY 1/2" BY 1" EXCEED SRM LIMIT. M/D BS 2200-2220 RBL 93 FLOOR SUPPORT REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D BS 2208 RBL 93 FLOOR SUPPORT FOUND CORROSION. CORROSION BLEND OUT 0.020" BY 1/2" BY 1" EXCEED SRM LIMIT. M/D BS 2200-2220 RBL 93 FLOOR SUPPORT REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.