What was found
INSPECTION TYPE:C M/D BS 1880 LBL50 TIE DOWN FTG FLANGE PLATE FOUND CORRODED. CORROSION BLEND OUT 0.080" BY 1/2" BY 1" EXCEED SRM LIMIT. TIE DOWN FTG PLATE REPLACED AS PER MM 20-51-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D BS 1880 LBL50 TIE DOWN FTG FLANGE PLATE FOUND CORRODED. CORROSION BLEND OUT 0.080" BY 1/2" BY 1" EXCEED SRM LIMIT. TIE DOWN FTG PLATE REPLACED AS PER MM 20-51-01.