What was found
INSPECTION TYPE-C M/D L5 DOOR LOWER HINGE LOWER WEB FOUND CORRODED. CORROSION BLEND OUT 0.063 INCH X 1INCH X 1.5 INCHES EXCEED SRM LIMIT. HINGE WEB REPLACED AND INSTALLED IAW SRM 51-10-01 PG 9 AND 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C M/D L5 DOOR LOWER HINGE LOWER WEB FOUND CORRODED. CORROSION BLEND OUT 0.063 INCH X 1INCH X 1.5 INCHES EXCEED SRM LIMIT. HINGE WEB REPLACED AND INSTALLED IAW SRM 51-10-01 PG 9 AND 51-30-02.