As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C M/D BS 940 RT TENSION TIE FWD STEEL PLATE UPPER ROW MOST I/B FASTENER HOLE SHORT OF EDGE MARGIN (1EA). M/D BS 940 RT TENSION TIE FWD CHANNEL ATTACHED STEEL PLATE REPAIRED AS PER HX RS R53-25-35642. CONTINUED INSPECTION REQUIRED AS PER HX RS R53-25-35642 AND UPS EO B747-5310-25518-A.