As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C M/D BS 800 RT TENSION TIE FWD STEEL PLATE UPPER AND LOWER ROW MOST I/B FASTENER HOLE SHORT OF EDGE MARGIN (SEM) 2 EACH. M/D BS 800 RT TENSION TIE FWD CHANNEL ATTACHED STEEL PLATE REPAIRED AS PER RS R53-25-35643. CONTINUED INSPECTION ARE REQUIRED AS PER RS R53-25-35643 AND UPS EO B747-5310-25512.