What was found
INSPECTION TYPE:C ON NR 2 PYLON, AFT BULKHEAD RT SIDE LOWER CORNER GOUGED BLKHD MILL AND NDT WERE DONE ON TRAV #T6/628543. GUSSET WAS FAB ON TR AV #T6/630053, FILLER WAS FAB ON TRAV #T6/630052. SHOT PEEN REWORKED AREA PER SOPM 20-10-03. LOCATED AND DRILLED GUSSET AND FILLER FINISHED REWORK AREA, FILLER AND GUSSET PER SOPM 20-43-03. INSTALLED REPAIR GUSSET AND FILLER PER FINAL EA 757-5453-27-A1533 STEPS 1-8.