As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C MAIN CARGO DECK FRAME AT STA 365 HAS CHAFE BETWEEN STR 15R-16R. PERFORMED PARTIAL BLEND OF AREA OF FRAME DIMENSIONS ARE AS FOLLOWS: L= .6, W= .6, D= .013, ORIGINAL DAMAGE STILL EVIDENT. REPAIR ACCOM ON EA 757-5332-27-A1557 AND UPS EO B757-5310-25339A W/ NO DEVIATIONS. PERFORMED DYE PENETRANT INSPECTION IAW SOPM 20-20-02 EA 757-5332-27-A1557. PRELIMINARY 1. NO CRACK INDICATIONS.