What was found
INSPECTION TYPE:N/A EMERGENCY DECLARED - LOSS OF BRAKING. CREW RECEIVED L HYD SYS PRESS MESSAGE. UPON TOUCHDOWN, APPLIED BRAKES WITH NO RESPONSE FROM BRAKE SYSTEM. PERFORMED 2 GO-AROUNDS. A/C LANDED SAFELY WITH NO FURTHER INCIDENT. (LEAKING FLEX LINE IN W/W). R&R LEFT EDP PER MM 29-11-05-4. REPLACED LEFT EDP CASE DRAIN FILTERS PER MM 29-11-17-4. NO CONTAMINATION NOTED. OPS AND LEAK CHECK GOOD.