What was found
INSPECTION TYPE:SIP NR 2 PYLON AFT BULKHEAD LT LOWER, OUTBOARDD CORNER CHAFED. MECH REQ. BULKHEAD MIL & NDT WERE DONE REF TRAV T6/641814. FILLER PLATE WAS FABBED ON TRAV T6/641938, GUSSETS WAS FABBED ON TRAV T6/641940. TREATED AND PRIMED GUSSETS, TREATED AND PRIMED REWORKED AREA. INSTALLED GUSSETS AND FILLERS PER FINAL EA 757-5453-27-1578 REPAIR INSTRUCTIONS 1-8 AND UPS EO B757-5410-25535-A.