INSPECTION TYPE:C2 MAIN CARGO DECK, BS 1197+22, LBL 20 TO RBL 20, WL 200, FLOORBEAM CORRODED. REPAIRED FLOORBEAM AT BS 1197+22 IAW GOODRICH ENGINEERING REPAIR NO 06-2725, RAA 767-53-20031 DTD 14AUG06.