What was found
INSPECTION TYPE:C2 MAIN CARGO FLOOR SUPPORT STRUCTURE HAS CORROSION AROUND THE UPPER AND LOWER SURFACE OF NUMEROUS FASTENER HOLES FROM BS 1461 TO BS 1518, RBL 89. REMOVED CORROSION BY MECHANICAL MEANS-AREAS "IN LIMITS" WERE ALODINED, PRIMED, AND PAINTED AREAS "OUT OF LIMITS". REMOVED AND REPLACED SEAT TRACK BS 1363-1505 RBL 89 AND TRANS PLATE BS 1505-1518 RBL 89 WL.200 TRANS PLATE P/N 146T5204-10.