What was found
INSPECTION TYPE:C1 MAIN DECK STA 702 L13R SPLICE FITTING IS CRACKED ON O/B SIDE. REMOVED CRACKED FITTING IAW SRM 51-1-20C, FABRICATED AND INSTALLED SPLICE FITTING IAW DWG 3779978, AND SRM 51-1-8, AND 51-1-20D AT STA 702 L13R
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1 MAIN DECK STA 702 L13R SPLICE FITTING IS CRACKED ON O/B SIDE. REMOVED CRACKED FITTING IAW SRM 51-1-20C, FABRICATED AND INSTALLED SPLICE FITTING IAW DWG 3779978, AND SRM 51-1-8, AND 51-1-20D AT STA 702 L13R