What was found
INSPECTION TYPE:C1 MAIN CARGO DOOR JAMB PLATE,THRESHOLD ATTACHED ANGLE CRACKED 1/4" AT FWD LATCH SPOOL. REMOVED, FABRICATED AND INSTALLED REPLACEMENT ATTACH ANGLE IAW SRM 51-3-0 AND DWG NR 5772786. TVL # 7268745.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1 MAIN CARGO DOOR JAMB PLATE,THRESHOLD ATTACHED ANGLE CRACKED 1/4" AT FWD LATCH SPOOL. REMOVED, FABRICATED AND INSTALLED REPLACEMENT ATTACH ANGLE IAW SRM 51-3-0 AND DWG NR 5772786. TVL # 7268745.