What was found
INSPECTION TYPE:C1 RT W/W FWD BULKHEAD STA 857 PRESSURE WEB LOWER ATTACH ANGLE CRACKED FROM RBL 24-33. REMOVED PRESS PANEL AND CUT OUT CRACKED AREA IAW SRM 51-1-21, AND 51-1-20D. FABRICATED AND INSTALLED -15 SPAR SECTION, -3, -5, AND -15 FILLERS, AND -14 STRAP IAW SRM 53-02-05 FIG 16, 53-2-5 FIG 6, 51-3-0, AND SRM 51-1-20D AT STA 857 RBL 12.66 - RBL 47.