What was found
INSPECTION TYPE:C1 CRACK AT STA 1766 LONG 4R ON "L" BRACKET. REMOVED DAMAGED ANGLE IAW 51-01-21, FABRICATED AND INSTALLED ANGLE ATTACHED TO AFT PRESS PANEL AT STA 1766, L4R IAW DWG 5773844, AND SRM 51-01-20D-0, 51-1-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1 CRACK AT STA 1766 LONG 4R ON "L" BRACKET. REMOVED DAMAGED ANGLE IAW 51-01-21, FABRICATED AND INSTALLED ANGLE ATTACHED TO AFT PRESS PANEL AT STA 1766, L4R IAW DWG 5773844, AND SRM 51-01-20D-0, 51-1-8.