As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C2 LONGERON END FITTING AT STA 1690 L24L HAS CORROSION INSIDE OF FITTING. REMOVED END FITTING AT STA 1690 L24L CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-02-00-0, LOCATED AND DRILLED REPLACEMENT END FITTING AND INSTALLED IAW SRM 51-1-21, 51-1-20D AND SRM 51-3-0.