What was found
INSPECTION TYPE:C1 EXFOLIATION CORROSION FOUND AT STA 70 STRUCTURE BETWEEN L31R AND L32R. CUT OUT DAMAGED STRUCTURE AT STA 70 BETWEEN L31R AND L33R IAW SRO 08538006, AND SRM 53-02-05. FABRICATED AND INSTALLED DOUBLER CHORD, AND SPLICES IAW SRO 08538006, AND SRM 53-2-5 FIG 8, 53-02-05, 51-1-24, 51-1-8.