What was found
INSPECTION TYPE:C1 PANEL LANDING AT ACCESS PNL 506C HAS DEEP GOUGE NR 3 MAIN TANK. TRIMMED OUT DAMAGED AREA OF LANDING IAW SRM 57-02-01 FIG 036. FABRICATED INSTALLED REPAIR FILLER, EXTERIOR DOUBLER, INTERIOR FILLER AND DOUBLER IAW SRM 57-02-01 FIG 036, 51-01-26-0, 51-3-2, AND SRM 51-1-8.