What was found
INSPECTION TYPE:C3 CLIP AT STRINGER 66 AND XRS 204 IS CRACKED NR 4 MAIN REMOVED CRACKED STRINGER CLIP AT STA XRS 204 NR 3 MAIN TANK IAW SRM 51-1-20D. FABRICATED AND INSTALLED CLIP AT STA XRS 204 NR 3 MAIN TANK IAW SAA EA NR 008-5710-01-A0421, UPS RAA DC8-57-20191, FAA FORM 8100-9,AND BOEING SRID 1-228171918