What was found
INSPECTION TYPE:C EMPENNAGE-BARREL NUT HOLE NR 30 LT FOUND BEARING WITH SURFACE CORROSION ON SIDE AND BOTTOM AREA. CORROSION REMOVAL C/OUT AFFECTED AREA PER SRM51-21-01.V2.R38, FOUND BLEND OUT EXCEEDED LIMIT PER MD11-5510-19409-K, REPAIR SLEEVE BUSHING FAB PER MD11-5510-19409-K, APPLIED SEALANT PR1422B 1/2 ON SLEEVE AND BORE AREA. INSTALLED SLEEVE BUSHING ON B/N HOLE NR 30 LT BORE. REPAIR ACCOMPLISHED AT B/N HOLE NR 30 LT PER EN 1040-06 AND EN 1638-05, FOUND SATIS.