As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C RHW DROOP L/E SLAT LWR I/B EDGE FOUND CHAFING MARK. CHAFING MARK BLENDED AND PROTECTED PER SRM51-21-01.V2.R.38.ORI THK 0.069 MAT REMOVED 0.055", REMAIN MAT THK 0.014", FOUND EXCEEDED LIMIT. REWORKED AREA EDGE TRIMMING FOUND REMAIN MAT THK 0.035". FASTENER EDGE DISTANCE IS 0.312" AND FASTENER HOLE SIZE IS 0.157" WITHIN LIMIT PER EN1005-06. RE WORK ACCOMPLISHED PER EN1005-06, FOUND SATIS.