What was found
INSPECTION TYPE:C LHW UPP SURFACE FIXED L/E AREA AT STA XRO 1192 APP (ON TOP LT NR 8 SLAT O/B EDGE AREA) FOUND CHAFF MARK. CHAFF MARK PER A/M DISCREPANCY BLENDED AND PROTECTED PER SRM 51-21-01.V2. R38.ORI THK 0.065,MAT REMOVED 0.031" FOUND EXCEEDED LIMIT. DAMAGED AREA TRIMMED DIA 1 1/2 BY 4 PER EN1042-06. HFEC INSP C/OUT, FOUND SATIS. NO CRACK EVIDENT. REPAIR SKIN FAB AND MAT USE 6061-0-0.063" BARE PER EN1042-06 REPAIR, WELDING AND GRINDING PER EN1042-06, FOUND JOB ACCOMPLISHED, SATIS.