What was found
INSPECTION TYPE:C EMPENNAGE - BARREL NUT HOLE 22 LEFT FOUND BEARING WITH SURFACE CORROSION ON SIDE & BOTTOM AREA. CORROSION REMOVAL C/OUT & FOUND BLENDED OUT BEYOND ALLOWABLE LIMIT. BARREL NUT HOLE NR 22 LT BORE REWORKED PER EN1032-06. FAB SLEEVE BUSHING PER EO MD11-5510-19409-K, FIG-5. APPLIED SEALANT PR1422B1/2 BLEND OUT AREA & S/ BUSHING PER EO MD11-5510-19409-K. REPAIR ACCOMPLISHED AT BARREL NUT HOLE 22 LEFT PER EO MD11-5510-19409-K & EN1032-06, FOUND SATIS.