What was found
INSPECTION TYPE:C EMPENNAGE - BARREL NUT HOLE 18 LEFT FOUND BEARING WITH SURFACE CORROSION ON SIDE & BOTTOM AREA. CORROSION REMOVAL C/OUT & FOUND BLENDED OUT BEYOND ALLOWABLE LIMIT. BARREL NUT HOLE 18 LEFT BORE & BOTTOM REWORKED PER EN1636-05. FAB SLEEVE BUSHING PER EO MD11-5510-19409-K, FIG-5. APPLIED SEALANT PR1422B1/2 BLEND OUT AREA & S/BUSHING PER EO MD11-5510-19409-K. REPAIR ACCOMPLISHED AT BARREL NUT HOLE 18 LEFT PER EO MD11-5510-19409-K & EN1636-05, FOUND SATIS.