What was found
INSPECTION TYPE:C RT WING TOP SIDE FIXED T/E PANEL XORS 683.4 FWD OF NR 4 SPOILER FOUND CORROSION UNDERNEATH PNL. CORROSION REMOVAL C/OUT FOUND MAT REMOVED EXCEEDED LIMIT. HFEC C/OUT FOUND NO EVIDENT OF CRACK. FLAP PEENING C/OUT ON REWORK AREA PER EN1039-0 6. REPAIR FILLER FAB USING MAT 7075T6-0.090" PER EN1039-06. UPPER SKIN APP STA XORS 670 TO 697 HI-LOK INSTALLED PER SRM51-33-01,V2.R.38. FIXED T/E UPPER PNL INSTALLED PER SRM 51-33-.01.V2.R.38, FOUND SATIS.